Data Center Controls & Monitoring

Coordinate cooling controls, electrical monitoring and critical alarms for data centers. Define what facilities and IT teams need to see and how they respond when a system changes state.

Operator view

Dashboard and HMI

Explore an illustrative interface with sample readings and events. Screen design and functions vary by project and platform.

ECOLEAD CONTROLS

Data Center Operations

Example facility · Cooling and electrical overview

Sample data
IT load
410 kW
Supply air
19.8 °C
Cooling units ready
6 / 6
Electrical demand over the daykW · 0–500
28206:00
30407:00
33308:00
36609:00
39010:00
41011:00
39712:00
38513:00

CRAH-04 · Filter warningFacilities review

Critical systems · Cooling and power status

  1. UPS A62% load
  2. UPS B58% load
  3. CRAH-04Filter warning
  4. Cold aisle22.1 °C
  5. Leak detectionNormal
Point or deviceReading or stateDetail
UPS AOn lineSample load 62%
CRAH-04RunningFilter warning
Cold aisle sensor22.1 °CWithin sample limits
Leak detection zone 1NormalNo active event

Solution design

System architecture and scope

A data center integration scope starts with the mechanical and electrical design. The BMS can manage cooling sequences, while electrical power monitoring collects readings from the agreed equipment. An interface to DCIM can share selected data with IT operations when the platforms support it.

  1. Cooling & sensors
  2. Electrical metering
  3. BMS / EPMS
  4. Operator view / DCIM

Cooling and environment

Integrate agreed plant and room equipment, including chillers, pumps, CRAC or CRAH units and temperature or leak sensors. Verify operating modes and alarm responses against the approved sequences.

Electrical visibility

Monitor status signals and available readings for UPS units, switchgear, generators and selected power distribution equipment. Define the boundary between electrical protection, monitoring and operator control.

Alarms and handover

Define alarm priorities, reporting, trend history and incident escalation. Test device, network and system interfaces against the approved commissioning plan.

Typical project deliverables

An integration matrix, points and alarm schedules, mechanical and electrical graphics, trend plans and agreed commissioning records. Certification and availability requirements are defined separately by the project team.

Manufacturer references

Platforms and devices

Schneider Electric Power Monitoring Expert

Electrical power monitoring reference for data center applications.

Manufacturer documentation

ECOLEAD CONTROLS

Tell us about your next project.

Share your requirements with our Damascus team. We can discuss the system scope and the next steps.